Improving the efficiency of commercial heating, ventilation and air conditioning (HVAC) systems can deliver significant benefits for organisations seeking to reduce energy consumption and operating costs. Implementing an energy-saving measure is not the same as demonstrating that it has worked, however…
A building may consume less energy following changes to its heating controls, but was the reduction caused by those adjustments or simply by milder weather?
A ventilation system might use less electricity after operating schedules are revised, but is it still providing adequate fresh air?
And while a new building management system (BMS) may generate extensive performance data, that information has limited value unless energy managers can use it to make informed decisions.
The Carbon Trust identifies controls, maintenance and reducing unnecessary demand as important opportunities for improving HVAC efficiency.
Meanwhile, CIBSE’s TM63 guidance provides a framework for evaluating energy performance in use, including the differences between expected and actual results.
For energy managers, the challenge is turning operational improvements into measurable, sustainable outcomes.
Following our first two November articles on selecting and optimising commercial HVAC systems, this final instalment examines how organisations can monitor performance, verify savings and maintain suitable building conditions over time.
The objective isn’t simply to use less energy. It’s to demonstrate that less energy is being wasted while the building continues to perform as intended.
At a Glance: Measuring HVAC Performance
| Area to measure | Why it matters | What to monitor |
|---|---|---|
| Energy consumption | Establishes actual resource use | Gas and electricity demand, HVAC submetering |
| Energy efficiency | Helps compare performance over time | Normalised consumption, system efficiency and operating hours |
| Building comfort | Ensures savings do not compromise occupants | Temperature, complaints and thermal comfort |
| Ventilation performance | Confirms appropriate fresh-air provision | Airflow, system operation and relevant indoor air quality indicators |
| Equipment reliability | Identifies faults affecting efficiency | Run hours, alarms, breakdowns and maintenance |
| Verified savings | Demonstrates the value of improvements | Baselines, adjusted consumption and measured outcomes |
Establish a Reliable Performance Baseline
Before measuring improvement, organisations need to understand how their HVAC systems were performing previously.
A baseline provides the reference against which subsequent changes can be assessed.
This may involve collecting information about energy consumption, operating schedules, building occupancy and relevant environmental conditions.
For example, an office building might establish how much gas and electricity it used during a representative period before making changes to heating controls.
However, energy managers should recognise that consumption will vary with factors such as weather and occupancy.
A baseline based on an unusually mild winter may not provide a suitable comparison with a colder period.
CIBSE’s TM63 guidance addresses the use of measured building information and calibrated models to evaluate operational energy performance.
The objective should be to establish a credible starting point that reflects how the building normally operates.
Without that baseline, organisations may struggle to distinguish genuine savings from changes in circumstances.
Understand the Difference Between Energy Reduction and Energy Savings
A reduction in energy consumption does not necessarily demonstrate improved efficiency.
A commercial building might use less heating energy because fewer people are working on site.
Another may experience lower electricity demand after reducing its opening hours.
These changes reduce consumption but do not automatically mean the HVAC system itself has become more efficient.
Energy managers should therefore consider how operational conditions affect performance.
A measurement and verification approach can help compare actual consumption with the energy that would reasonably have been used under equivalent conditions without the improvement.
Relevant factors may include external temperature, building occupancy and operating hours.
The result provides a more meaningful estimate of the benefit delivered by an intervention.
Using less energy is a useful outcome. Understanding why it happened is what makes the improvement repeatable.
Use Submetering to Improve Visibility
Whole-building energy bills provide useful information, but they rarely explain exactly how HVAC systems are performing.
Electricity consumption may include lighting, equipment, IT infrastructure and other activities alongside ventilation and cooling.
Gas consumption may also support domestic hot water or other services.
Submetering can help organisations distinguish relevant energy uses.
Depending on the building, this might involve monitoring heating plant, ventilation fans, chillers or other major equipment.
However, additional meters should be selected according to a clear purpose.
Installing numerous monitoring devices can increase cost and data management requirements without necessarily improving decisions.
Energy managers should establish which systems account for significant energy use and where greater visibility would support action.
The priority is to collect information that helps identify inefficiencies and evaluate improvements.
Build an HVAC Performance Scorecard
An effective scorecard should connect energy consumption with the conditions being delivered inside the building.
| KPI | What it tells you | Question to ask |
|---|---|---|
| HVAC energy consumption | Energy used by relevant heating, ventilation and cooling equipment | Is consumption changing as expected? |
| Weather-adjusted energy use | Energy performance after accounting for weather differences | Are reductions attributable to improvement rather than climate conditions? |
| Energy use intensity | Consumption relative to a defined building area and period | How does this building compare with its own baseline or suitable benchmarks? |
| Out-of-hours operation | Equipment activity outside required operating periods | Are systems running unnecessarily? |
| Indoor temperature compliance | Whether relevant spaces remain within agreed conditions | Are comfort requirements being maintained? |
| Ventilation performance | Whether required fresh-air provision is being delivered | Are energy reductions affecting air quality? |
| Equipment faults and run hours | Reliability and operation of plant | Are faults or excessive run times increasing consumption? |
| Verified energy savings | Estimated or measured benefits attributable to changes | Did the intervention deliver its intended result? |
Not every building requires every measure. The appropriate scorecard will depend on the systems installed, the available information and the organisation’s objectives.
A relatively simple office may need a smaller set of indicators than a complex commercial building with centralised heating, cooling and ventilation plant.
The objective is to make performance understandable and actionable.
Use Building Management System Data Effectively
A building management system can provide information about how HVAC equipment operates.
Depending on its capabilities and configuration, this may include temperature readings, setpoints, equipment status, operating schedules and fault alarms.
However, simply collecting information does not guarantee better performance.
Energy managers should establish which trends are worth reviewing and how anomalies will be investigated.
For example, a heating system operating during unoccupied hours may indicate that schedules or overrides need attention.
Repeated simultaneous heating and cooling demands could suggest poorly coordinated control settings.
A ventilation fan operating continuously may warrant investigation into its required airflow and operating schedule.
The objective should be to identify patterns that support corrective action.
A BMS should be used as an active management tool rather than simply a record of what the building has done.
Monitor Comfort Alongside Consumption
HVAC optimisation should not be judged through energy consumption alone.
A building may use less energy after heating setpoints are reduced, but occupants could experience unacceptable cold conditions.
Similarly, reducing cooling activity might create overheating in areas exposed to significant solar gain.
The Health and Safety Executive (HSE) explains that thermal comfort depends on several factors, including air temperature, radiant temperature, humidity, air movement, clothing and physical activity.
Energy managers should therefore assess relevant building conditions alongside energy use.
Temperature monitoring can provide useful information, but employee feedback is also important.
Complaints about uncomfortable conditions may reveal problems with zoning, controls or equipment performance.
The objective should be to improve efficiency without undermining the working environment.
Verify Ventilation Performance
Ventilation presents a particular challenge because reducing fan operation may appear to deliver immediate electricity savings.
However, employers must provide adequate fresh air in enclosed workplaces.
The HSE advises organisations to assess ventilation requirements and identify areas where fresh-air provision may be insufficient.
Energy managers should establish whether ventilation optimisation measures maintain the necessary conditions.
Depending on the building, this may involve reviewing airflow measurements, system operation, occupancy and suitable indoor air quality indicators.
Carbon dioxide monitoring can provide useful information about ventilation in some occupied spaces.
However, CO₂ readings should be interpreted appropriately and are not a complete measure of indoor air quality.
They also do not replace the need for suitable system design and maintenance.
The aim should be to remove unnecessary ventilation energy while maintaining adequate fresh-air provision.
Evaluate Operating Schedules
Many HVAC inefficiencies arise because systems operate longer than necessary.
Heating might begin several hours before a building becomes occupied, while ventilation may continue operating after employees have left.
Energy managers should compare programmed schedules with actual building usage.
BMS trend information and equipment run-hour data can help identify unnecessary operation.
However, system schedules must reflect the characteristics of the building.
Some properties require earlier heating to reach suitable conditions before occupancy.
Others may need ventilation or environmental control outside normal working hours.
A change to operating schedules should therefore be assessed according to the resulting conditions as well as energy savings.
The objective is to eliminate unnecessary activity rather than apply indiscriminate shutdown periods.
Review Heating and Cooling Interactions
Some commercial buildings experience unnecessary energy consumption because heating and cooling systems operate against one another.
This can occur where temperature settings overlap, controls are incorrectly configured or different systems respond independently.
BMS information may help identify these situations.
For example, a zone showing simultaneous demand for heating and cooling could warrant investigation.
However, some systems have legitimate operational requirements that may create apparently overlapping demands.
Energy managers should therefore work with competent building services specialists to understand the control strategy before making changes.
Where genuine conflicts are identified, adjustments may reduce energy consumption and improve comfort.
The objective should be coordinated system operation rather than simply reducing equipment output.
Track Maintenance and Equipment Reliability
Maintenance influences both energy efficiency and operational reliability.
A faulty sensor, sticking valve or poorly maintained heat exchanger may cause equipment to consume more energy than necessary.
Dirty filters can also affect airflow and system performance.
The Carbon Trust identifies maintenance as an important element of effective HVAC energy management.
Energy managers should therefore examine maintenance information alongside consumption trends.
Useful questions include whether particular equipment generates repeated faults, whether repairs have affected energy use and whether planned maintenance is being completed.
A sudden increase in fan electricity consumption, for example, could justify investigating filters, airflow resistance or equipment operation.
The objective is to identify maintenance problems before they become persistent sources of waste or disruption.
Measure Heat Recovery Performance
Heat recovery systems can reduce the energy required to condition incoming fresh air.
However, their performance depends on suitable operating conditions and correctly functioning equipment.
Energy managers should establish whether heat recovery is delivering the expected benefit.
This may involve reviewing relevant temperatures, airflow, operating conditions and control settings.
Bypass controls also require attention.
In some circumstances, bypassing heat recovery is appropriate to avoid unnecessary heating or allow beneficial cooling.
Poorly configured arrangements may increase energy use.
The important point is to evaluate heat recovery as part of the complete ventilation system.
A theoretical efficiency figure does not necessarily demonstrate the benefit achieved during actual building operation.
Compare Buildings Fairly
Organisations managing multiple properties may want to compare HVAC performance across their portfolio.
However, simple energy consumption rankings can be misleading.
A large, heavily occupied building may consume more energy than a smaller property while operating more efficiently.
Likewise, sites can differ significantly in age, construction, operating hours and ventilation requirements.
Energy managers should establish appropriate performance indicators.
Energy use intensity, expressed in kWh per square metre over a defined period, can provide a useful starting point.
However, it should not be treated as a complete measure of efficiency.
Comparisons may also need to consider occupancy, weather, building use and relevant operational characteristics.
A portfolio review should help identify buildings requiring investigation rather than create simplistic rankings.
Use Measurement and Verification to Demonstrate Results
Measurement and verification provides a structured approach to evaluating the effect of energy-saving measures.
It generally involves establishing a baseline, documenting relevant changes and comparing subsequent performance against an appropriately adjusted reference.
CIBSE’s TM63 guidance provides a methodological framework for evaluating energy performance in use and investigating differences between expected and actual results.
For example, an organisation might introduce improved heating schedules and then examine energy consumption during a suitable monitoring period.
The analysis should account for relevant differences in weather and operating conditions.
The complexity of the approach should reflect the scale and significance of the intervention.
A minor adjustment to an operating schedule may not require the same level of analysis as a substantial investment in heating plant.
The important principle is to make savings claims proportionate, transparent and supported by appropriate evidence.
Avoid Common Measurement Mistakes
HVAC performance reporting can produce misleading conclusions when information is incomplete or interpreted without context.
Common mistakes include:
- Comparing different weather conditions without adjustment. A mild winter may make heating consumption appear more efficient.
- Ignoring occupancy changes. Reduced building use can lower demand independently of technical improvements.
- Treating all energy reductions as verified savings. Consumption can fall for reasons unrelated to an intervention.
- Using unrepresentative baseline periods. A short or unusual period may distort the comparison.
- Overlooking comfort and ventilation. Lower energy use is not a positive outcome if appropriate building conditions are no longer maintained.
- Relying on estimated rather than observed performance. Supplier projections should be checked against actual operation where possible.
- Collecting data without acting on it. More detailed reports will not improve efficiency unless they inform decisions.
Energy managers should establish how these risks will be addressed before drawing conclusions.
Make Savings Part of Financial Reporting
HVAC improvements are frequently justified through anticipated reductions in energy costs.
However, changes in tariffs and market prices can complicate financial comparisons.
For example, an organisation might reduce gas consumption but still face a higher bill because the unit price has increased.
Energy managers should therefore distinguish between energy savings and financial savings.
Energy reductions can be reported in kWh, while financial benefits should be calculated using appropriate assumptions about prices and other relevant costs.
Where an investment has been made, the analysis may also consider capital expenditure, maintenance requirements and ongoing operational costs.
A useful report should explain what has changed, how savings were established and whether the expected return is being achieved.
The objective is to give senior decision-makers confidence in the results.
Connect HVAC Improvements with ESOS Reporting
For organisations within the scope of the UK’s Energy Savings Opportunity Scheme (ESOS), demonstrating progress on energy efficiency has additional relevance.
Under Phase 3, qualifying organisations must prepare action plans and submit progress updates identifying implemented measures and estimated energy savings.
The second progress update deadline is 5 December 2026.
Government guidance requires organisations to identify relevant measures, report implementation progress and explain the methods used to estimate savings.
HVAC improvements may form part of this reporting where appropriate.
However, ESOS requirements apply to qualifying organisations, rather than every commercial building operator.
Energy managers should establish the obligations relevant to their organisation and maintain suitable supporting evidence.
Even where formal ESOS reporting is not required, the principle of documenting actions and outcomes provides a useful management discipline.
Build a Regular HVAC Performance Review
HVAC performance changes over time.
Building occupancy may increase or decline, control settings may be altered and equipment performance can deteriorate.
Energy managers should therefore establish a regular review process rather than rely on occasional audits.
A practical six-step checklist is:
- Review consumption. Examine relevant heating, ventilation and cooling energy use against an appropriate baseline.
- Check operating conditions. Confirm whether occupancy, weather and operating hours explain significant changes.
- Investigate exceptions. Identify unusual run times, control conflicts, faults and unexpected energy demand.
- Confirm building conditions. Review temperature, ventilation performance and relevant occupant feedback.
- Assign corrective action. Agree which operational or maintenance teams are responsible for improvements.
- Verify the results. Assess whether the changes reduced unnecessary energy use without compromising building performance.
This process should involve energy managers, facilities teams and relevant maintenance specialists.
The objective is to identify emerging problems and maintain improvements rather than allow systems to drift back towards inefficient operation.
Questions to Ask HVAC Performance and Monitoring Providers
When reviewing monitoring, controls and optimisation services, energy managers should consider:
- How will current HVAC performance be assessed?
- What data is required to establish a suitable baseline?
- Can heating, ventilation and cooling energy use be distinguished?
- How will weather and occupancy changes be considered?
- Can BMS data identify unnecessary operating hours?
- What measures identify simultaneous heating and cooling?
- How will indoor comfort and ventilation performance be monitored?
- Can the system identify emerging equipment faults?
- How are maintenance records connected to energy performance?
- What reporting is available across multiple buildings?
- How will savings be measured and verified?
- Can estimated energy savings be distinguished from measured results?
- What information supports financial and sustainability reporting?
- How are corrective actions assigned and reviewed?
- What evidence demonstrates that improvements have been sustained?
Frequently Asked Questions
How is commercial HVAC efficiency measured?
HVAC efficiency can be assessed through energy consumption, system-specific performance indicators, operating hours and the conditions delivered within the building. Appropriate comparisons should account for relevant factors such as weather and occupancy.
What is measurement and verification in energy management?
Measurement and verification is a structured process used to establish whether energy-saving measures have delivered the expected results, typically by comparing performance with an appropriately adjusted baseline.
Can a BMS help measure HVAC performance?
Yes. A building management system can provide information about operating schedules, temperatures, equipment status and energy-related trends, depending on its configuration and connected devices.
Why should HVAC energy use be weather-adjusted?
Heating and cooling demand can vary substantially with outdoor conditions. Weather adjustment helps energy managers distinguish technical improvements from changes caused by warmer or colder periods.
How can organisations measure building comfort?
Relevant measures may include indoor temperature, humidity, air movement and occupant feedback. The HSE advises that thermal comfort depends on several environmental and personal factors.
How often should HVAC performance be reviewed?
Monitoring frequency should reflect building complexity and operational risk. Significant faults or unusual consumption may require prompt investigation, supported by regular performance reviews and seasonal assessments.
Turn Energy Data into Lasting Improvement
Measuring HVAC performance should involve more than reporting consumption or celebrating reductions in utility bills.
Energy managers need to understand whether systems are operating efficiently, whether improvements have delivered genuine savings and whether suitable conditions are being maintained for building users.
A practical performance framework is: measure → understand → act → verify → sustain
Measure current performance using appropriate data.
Understand the factors influencing consumption.
Act on unnecessary energy use and operational weaknesses.
Verify that improvements have delivered the intended results.
Then sustain those benefits through ongoing monitoring and review.
The strongest HVAC performance strategy isn’t necessarily the one producing the largest estimated energy saving.
It’s the one that can prove energy is being used more efficiently, building conditions are being maintained and improvements continue to deliver value over time.
The Energy Management Summit brings together senior energy, sustainability, estates and facilities decision-makers with relevant solution providers through pre-arranged one-to-one meetings, offering an opportunity to explore HVAC monitoring, building controls, energy efficiency, maintenance and wider building performance solutions.
Related Reading
This is the third and final article in our November Heating & Ventilation / HVAC series.
Article #1: Commercial Heating & Ventilation Systems: What Energy Managers Should Compare explored heating technologies, ventilation requirements, heat recovery, controls and whole-life costs.
Article #2: Heating & Ventilation Optimisation: How to Cut Energy Waste Without Compromising Comfort examined operational improvements through better schedules, setpoints, zoning, ventilation controls and maintenance.
Article #3 completes the series by examining how organisations can measure HVAC efficiency, verify energy savings and maintain performance over time.
Together, the articles provide a practical framework for selecting suitable systems, improving their operation and demonstrating the results.
Sources
- Carbon Trust – Heating, Ventilation and Air Conditioning Guide
- CIBSE – TM63: Operational Performance and Measurement & Verification
- HSE – Ventilation in the Workplace
- HSE – Assessing the Risk of Poor Ventilation
- HSE – Thermal Comfort
- HSE – Keeping a Comfortable Temperature
- GOV.UK – ESOS Phase 3 Guidance
- GOV.UK – Complying with ESOS Phase 3
Image credit: https://unsplash.com/photos/air-conditioner-remote-in-wall-holder-tQ2Tv_udZZ4